首页 > 产品中心 > Fume & dust treatment > Equipment and System for Removal of Dioxin in the Fly Ash from Waste Incineration
产品简介
Equipment and System for Removal of Dioxin in the Fly Ash from Waste Incineration
The destruction system of fly ash dioxins from waste incineration can break down and remove dioxins in fly ash, and can operate continuously and stably. The dioxins removal rate can be over 99% and the dioxin content in treated fly ash is controlled within 50ng-TEQ/kg (as per dry basis of fly ash) which can meet the requirements of Technical Specification for Pollution Control of Fly Ash From Municipal Solid Waste Incineration (HJ1134-2020). As a key link in utilization of fly ash resources, this system’s process and throughput can be customized according to clients’ demands.
- 规格系列:ENFI-De-PCDD/Fs-1/5/10/20/30
- 处理能力:Customized capacity of 0-30t/d (as per dry basis of fly ash)
- 适用领域:Location: indoor installation; Plant voltage class: AC: 380V/220V, 50H; Requirements of nitrogen quality: pressure≮0.6MPa, purity≮99.99%.
服务电话+86 13521339794
获取价格
在线留言
enfi.cemsa@gmail.com
优势特点
- Continuous operation; low-temperature treatment; dioxins destruction rate>99%.
工作原理
Under the anaerobic environment, in a suitable temperature range and residence time, the Cl chemical bond in solid-phase PCDD/Fs can break down into inorganic Cl-, realizing dioxins destruction.
技术参数
Technical Data Sheet | |
---|---|
Maximum design temperature: | 550℃ |
Normal working temperature: | 350-500℃ |
Oxygen content during normal operation: | ≤130ppm |
Furnace tube section size | Diameter: φ300mm-φ1500mm |
Heating method: | Horizontal/annular heating |
Temperature control: | Temperature control in groups |
Furnace temperature fluctuation range: | ±2℃/2H (indicated by temperature controller) |
Furnace tube rotating speed: | 0.5-2r/min, continuously variable, VSD; |
Furnace body inclination angle: | 0–1°; |
Installed power: | 20~600Kw |
应用业绩
相关推荐